Mila Pamplona
2071 Views

What’s new on EEG?

BrainAmp II - Next-Generation High-Performance EEG Amplifiers | Technical Overview and SfN 2026 Launch

BrainAmp II and BrainAmp II MR by Brain Products — Scalable EEG acquisition, referential and bipolar recording, up to 20 kHz sampling, TMS-EEG, multimodal electrophysiology and simultaneous EEG-fMRI up to 7 Tesla.

1. Introducing BrainAmp II: A New Generation of EEG Amplification

Unveiled at Neuroscience 2026 (SfN 2026), Washington, D.C., November 14–18, BrainAmp II is the latest generation of research-grade electrophysiological amplifiers developed by Brain Products.

Designed for advanced neuroscience applications, the BrainAmp II platform introduces flexible channel configurations, high dynamic range, high sampling rates and integration capabilities for complex experimental setups.

sfn2026 High-performance EEG
sfn2026 High-performance EEG

The new product family comprises two principal amplifier platforms:

  • BrainAmp II: Designed for research laboratories performing EEG, ERP, TMS-EEG, hyperscanning and multimodal physiological recording.

  • BrainAmp II MR: Designed for EEG acquisition in magnetic resonance environments, supporting simultaneous EEG-fMRI applications up to 7 Tesla.

The product ecosystem also introduces BrainVision Recorder 2 for signal acquisition and BrainVision Composer for online visualization and processing.

Together, these components form a new hardware and software architecture for high-performance electrophysiological research.

2. BrainAmp II: Core Technical Specifications

The most important published capabilities of BrainAmp II are summarized below.

ParameterBrainAmp II
ManufacturerBrain Products GmbH
Product generationBrainAmp II
Acquisition architectureReferential and bipolar channels
Referential EEG capacityUp to 128 per amplifier
ExpansionMultiple amplifiers through extension sets
Maximum sampling rateUp to 20 kHz
Dynamic rangeHigh dynamic range
External eventsThird-party trigger integration
Peripheral physiologyBipolar ExG configurations
TMS-EEGSupported application
HyperscanningSupported application
Acquisition softwareBrainVision Recorder 2
MR environmentUse BrainAmp II MR instead

High sampling rates: up to 20 kHz

BrainAmp II supports sampling rates of up to 20,000 samples per second, corresponding to a nominal sampling interval of 50 microseconds.

This high sampling capability is relevant for studies requiring detailed representation of rapidly changing electrophysiological signals, including specialized TMS-EEG protocols.

However, sampling frequency should not be confused with effective signal bandwidth or temporal accuracy of the complete experimental system.

The useful signal bandwidth is also determined by the amplifier's analog front end, filtering, electrode-skin interface and acquisition configuration.

For conventional ERP recordings, lower sampling rates may already be sufficient. The ability to select higher rates provides flexibility for more demanding applications.

High dynamic range

BrainAmp II is designed to accommodate electrophysiological acquisition requirements involving signals with different amplitudes and recording conditions.

High dynamic range is particularly relevant when EEG measurements are performed in environments where large transient artifacts may occur, including combined TMS-EEG.

Detailed numeric specifications for input-referred noise, input impedance, analog-to-digital converter resolution, common-mode rejection ratio and input voltage range should be consulted in the model-specific technical documentation.

These parameters should not be inferred from the previous BrainAmp generation.

3. Referential and Bipolar Channels: A Flexible Recording Architecture

One of the distinguishing features of BrainAmp II is the integration of referential and bipolar recording configurations within the product family.

Referential EEG channels

Referential channels measure the electrical potential at each recording electrode relative to a designated reference.

They are commonly used for:

  • Resting-state EEG and spectral analysis.

  • Event-related potentials and event-related oscillations.

  • Cognitive and sensory electrophysiology.

  • TMS-evoked potential studies.

  • High-density scalp EEG.

  • Multichannel brain connectivity studies.

BrainAmp II offers configurations supporting up to 128 referential channels per amplifier.

Bipolar ExG channels

Bipolar recording measures the potential difference between two inputs and can be used with appropriate sensors for peripheral electrophysiology.

Depending on the configuration, bipolar channels may support:

  • Electrocardiography (ECG).

  • Electrooculography (EOG).

  • Electromyography (EMG).

  • Other compatible peripheral physiological recordings.

Combining referential EEG channels with bipolar ExG channels makes it possible to acquire central and peripheral electrophysiological measurements within an integrated recording system.

For example, a laboratory studying cognitive workload could record EEG activity alongside eye-movement and muscle-related signals, improving the characterization of experimental conditions and potential artifacts.

4. BrainAmp II Configurations: Systems and Extension Sets

The initial BrainAmp II release comprises 10 amplifier variants.

The naming convention identifies the amplifier family and its channel configuration.

For example:

BrainAmp II 128/0

This denotes a configuration containing 128 referential channels and no bipolar channels.

BrainAmp II MR 32/16

This denotes an MR-compatible configuration containing 32 referential channels and 16 bipolar channels.

The complete list of ten variants and their available ordering combinations should be confirmed against the manufacturer's current product catalog.

BrainAmp II complete systems

A BrainAmp II system includes the principal hardware required to connect the selected amplifier configuration to a recording computer and compatible electrodes or sensors.

The announced package includes:

  1. BrainAmp II amplifier.

  2. PowerPack II external battery.

  3. BrainAmp Hub interface box.

  4. BrainVision Recorder hardware dongle.

  5. Required system connection cables.

The acquisition software license is a separate purchasing item.

Important licensing requirement: BrainVision Recorder 2 is mandatory for BrainAmp II acquisition and must be purchased with a new system, even though the hardware dongle is already included.

BrainAmp II extension sets

Extension sets enable laboratories to expand an existing BrainAmp II installation with an additional amplifier.

For example, a non-MR setup can combine:

BrainAmp II 128/0 + BrainAmp II 128/0 = 256 referential EEG channels.

This illustrates the distinction between the capacity of one amplifier and the channel count of an expanded system.

When configuring multiple amplifiers, laboratories should verify supported synchronization, channel allocation, hub connectivity, cable requirements and software capacity for the intended installation.

5. Multimodal Physiology and the ExG AUX Box

BrainAmp II configurations incorporating bipolar modules can support peripheral electrophysiological measurements.

For standard configurations intended for peripheral physiology, an ExG AUX Box set is included where specified.

The ExG AUX Box provides the appropriate connection interface for supported physiological sensors.

The distinction between conventional laboratory ExG recording and MR-specific bipolar modules is important.

For example, the BrainAmp II MR 32/16 configuration is intended to support referential EEG together with bipolar acquisition at the head end, including artifact detection loops.

In this configuration, the ExG AUX Box is not included.

Researchers should therefore select channel modules based on their actual acquisition requirements rather than assuming that every bipolar configuration is intended for the same peripheral sensors.

6. BrainAmp II for TMS-EEG

Simultaneous transcranial magnetic stimulation and EEG is a technically demanding application.

TMS pulses can introduce large electromagnetic artifacts into EEG recordings. Additional artifacts can arise from electrode movement, muscle activation and other stimulation-related effects.

BrainAmp II has been designed with EEG-TMS among its principal applications.

Technical requirements in TMS-EEG

A successful combined TMS-EEG experiment requires careful consideration of:

  • Amplifier recovery after stimulation.

  • Input dynamic range and saturation behavior.

  • Electrode geometry and cable routing.

  • Trigger synchronization between stimulator and acquisition.

  • Separation of electromagnetic, muscular and sensory artifacts.

  • Reproducible preprocessing and artifact-rejection procedures.

During SfN 2026, Brain Products demonstrated combined EEG-TMS using BrainAmp II, including artifact-management approaches intended to recover usable signals approximately 2–5 ms after stimulation under the demonstrated conditions.

The actual recovery interval must be validated for each experimental configuration.

Snaptrode TMS electrode sets

The new Snaptrode TMS sets for BrainAmp provide a compatible passive electrode solution optimized for TMS applications.

Key characteristics include:

  • Passive gel-based electrodes.

  • 32-channel and 64-channel sets.

  • Electrode profile approximately 3 mm high.

  • Compatible actiCAP snap electrode caps.

  • Dedicated reference and ground electrodes.

  • Flexible electrode placement and cable routing.

  • Two electrode caps included in different selectable sizes.

Product references

32-channel set: BP-135-3000

64-channel set: BP-135-3010

The low electrode profile facilitates close positioning of the stimulation coil, while flexible cable routing helps accommodate different stimulation sites.

This electrode design can be particularly relevant in laboratories conducting repeated TMS-EEG experiments across different participants and head sizes.

7. BrainAmp II MR: Simultaneous EEG-fMRI Up to 7 Tesla

BrainAmp II MR is the MR-compatible member of the new amplifier family.

It is designed for simultaneous EEG acquisition within MRI research environments and supports use up to 7 Tesla, subject to the approved system configuration and safety requirements.

Main technical capabilities

  • MR-compatible EEG acquisition.

  • Operation in environments up to 7 Tesla.

  • Sampling rates up to 20 kHz.

  • High dynamic range.

  • Integration of referential EEG and appropriate bipolar modules.

  • Support for artifact detection loops.

  • Integration with MRI acquisition workflows.

EEG-fMRI artifacts

During simultaneous EEG-fMRI, several types of interference must be addressed.

Gradient artifacts

Rapidly switching MRI gradients induce electrical signals in the EEG recording system.

These artifacts can have amplitudes substantially larger than the physiological EEG signal.

Cardioballistic artifacts

Cardiac-related motion and associated electromagnetic effects produce artifacts that can contaminate the EEG recording.

Head-motion artifacts

Movement of the head, electrodes and associated wiring inside the magnetic field can induce additional interference.

BrainAmp II MR supports configurations incorporating Artifact Detection Loops, previously known as carbon-wire loops or CWLs.

These provide additional information that can be used for regression-based artifact reduction.

The new Composer software introduces online correction methods for these interference sources.

MR safety and compatibility

The stated compatibility up to 7 Tesla applies to the specified BrainAmp II MR system and must not be generalized to arbitrary accessories.

Researchers must verify compatible electrode caps, cables, loops, sensors and installation conditions.

The manufacturer's standard new-system onboarding program is specified for 3T installations; 7T deployment should be evaluated individually.

8. BrainVision Recorder 2: Acquisition Software for BrainAmp II

BrainVision Recorder 2 is required for EEG acquisition with BrainAmp II.

The new version provides an integrated environment for amplifier configuration, workspace management and recording control.

Its announced features include:

  • Centralized amplifier and workspace configuration.

  • Intuitive acquisition workflows.

  • Flexible configuration for complex laboratory arrangements.

  • Support for experimental triggers.

  • BIDS-friendly data output.

  • Lab Streaming Layer (LSL) streaming options.

For studies combining EEG, ERP, external stimulation and physiological recording, event integration and precise acquisition documentation are particularly important.

Software licensing

User categoryLicense
New BrainAmp II systemBP-270-3050
Upgrade from Recorder 1 ProfessionalBP-295-5001
Recorder 2 upgrade, one amplifierBP-295-5000

The appropriate upgrade route depends on the existing installation and licensing conditions.

A Recorder dongle is included in the BrainAmp II system package, but the Recorder 2 software license must be purchased separately.

9. BrainVision Composer: Online Processing for EEG-fMRI

BrainVision Composer is a new online signal visualization and processing environment intended to replace RecView.

Its architecture uses configurable processing nodes that can be connected to form analysis pipelines.

The initial release focuses on EEG-fMRI applications.

Node-based signal processing

Researchers can assemble processing chains without programming each operation from scratch.

Processing parameters can also be adjusted while the online workflow is running.

Online gradient artifact correction

Composer supports average artifact subtraction approaches for reducing MRI gradient contamination.

This approach uses the repetitive nature of gradient-related interference to estimate an artifact waveform and subtract it from the acquired data.

Artifact Detection Loop regression

Composer also supports regression-based correction using signals from artifact detection loops.

These auxiliary measurements can help estimate interference associated with cardioballistic effects and head movement.

Composer product information

Initial EEG-fMRI application: BP-270-2010.

An additional hardware dongle is required for the Composer software license.

Although online correction can improve monitoring during acquisition, offline verification and appropriate validation remain necessary for research-quality analysis.

10. BrainCap Compatibility and Updated MR Electrode Systems

BrainAmp II maintains compatibility with existing BrainCap families used by the previous BrainAmp generation.

Supported cap families include:

  • BrainCap.

  • BrainCap TMS.

  • BrainCap MR3.

  • R-Net MR3.

  • Compatible MR3 versions with artifact detection loops.

This continuity can simplify planning for laboratories upgrading from previous-generation systems.

Updated artifact detection loop caps

Brain Products is revising the MR-compatible caps incorporating artifact detection loops.

The updated design replaces the previous drop-down ECG lead with an electrode integrated into the cap.

This provides an additional EEG electrode while preserving the ability to use loop-based artifact-regression methods.

MR caps without artifact detection loops will continue to include an ECG lead, maintaining options for existing BrainAmp MR and MR Plus configurations that do not use an ExG MR amplifier.

11. EEG-fMRI Onboarding for BrainAmp II MR

Brain Products offers dedicated installation-oriented training for BrainAmp II MR systems.

EEG-fMRI Onboarding for BrainAmp II MR: BP-280-1002

The program includes two days of onsite training, with sessions structured around installation.

Training subjects include:

  • BrainAmp II MR safety guidelines.

  • MRI environment setup and equipment positioning.

  • Acquisition with BrainVision Recorder 2.

  • Online artifact correction using Composer.

  • Offline data handling and processing considerations.

The standard program is designed for 3T installations.

The associated regional travel item must be ordered separately to cover the onsite certified trainer's travel requirements.

12. Selecting the Right BrainAmp II Configuration

The optimal configuration depends on the scientific protocol, required channel count, recording environment and additional physiological measurements.

Research applicationConfiguration consideration
Cognitive EEG and ERPBrainAmp II with appropriate referential channel count
High-density EEGHigher-channel BrainAmp II configuration or expanded system
EEG with ECG, EOG or EMGBrainAmp II with suitable bipolar modules
TMS-EEGBrainAmp II with compatible TMS electrodes and stimulation synchronization
HyperscanningMultiple recording systems with validated synchronization
Simultaneous EEG-fMRIBrainAmp II MR
EEG-fMRI with artifact detection loopsBrainAmp II MR with compatible bipolar channels, loops and Composer

Before acquisition, research teams should establish the required channel topology, sampling rate, event synchronization, accessories, software licensing and any application-specific safety requirements.

These decisions influence data quality, reproducibility and the total system configuration.

13. BrainAmp II Technical FAQ

What is the maximum sampling rate of BrainAmp II?

BrainAmp II supports sampling rates up to 20 kHz. The selected operating rate and effective signal bandwidth should be verified for the specific configuration.

How many EEG channels does BrainAmp II support?

A single BrainAmp II amplifier can support up to 128 referential EEG channels. Extension sets allow multiple amplifiers to be combined in supported configurations.

Can BrainAmp II record EEG and peripheral physiology simultaneously?

Yes, configurations combining referential and bipolar recording modules can support EEG and compatible peripheral electrophysiological measurements.

What is the difference between BrainAmp II and BrainAmp II MR?

BrainAmp II is intended for non-MR research environments, while BrainAmp II MR is designed for MR-compatible acquisition and simultaneous EEG-fMRI up to 7 Tesla.

Is BrainAmp II compatible with existing BrainCaps?

Yes. BrainAmp II is compatible with the corresponding BrainCap families used with the earlier BrainAmp generation.

Does BrainAmp II work with BrainVision Recorder 1?

BrainAmp II acquisition requires BrainVision Recorder 2. Existing Recorder users may have access to applicable upgrade licensing options.

What is BrainVision Composer used for?

Composer provides node-based online signal processing and visualization. Its initial release focuses on EEG-fMRI artifact correction, including MRI gradient artifacts and regression using artifact detection loop measurements.

Is BrainAmp II suitable for TMS-EEG?

Yes. Brain Products identifies TMS-EEG as a principal application and provides compatible electrode solutions and acquisition integration.

Can BrainAmp II support 256-channel recordings?

A supported non-MR configuration can combine two BrainAmp II 128/0 amplifiers, providing 256 referential EEG channels.

Where was BrainAmp II introduced?

The new product generation was presented during Neuroscience 2026, the Society for Neuroscience annual meeting in Washington, D.C., November 14–18, 2026.

14. BrainAmp II in Latin America | BrainLatam

BrainLatam connects neuroscience laboratories and research institutions throughout Latin America with advanced EEG, electrophysiology and multimodal neurotechnology solutions.

For research groups evaluating BrainAmp II, the main technical considerations include amplifier architecture, EEG and ExG channel requirements, recording software, electrode compatibility, stimulation integration and MR-specific configurations.

Technical discussions can address complete systems, expansion options, existing BrainAmp installations, software upgrade paths and application-specific accessories.

Interested in BrainAmp II or BrainAmp II MR for your research laboratory?

Contact BrainLatam to discuss the configuration best suited to your experimental protocols.

BrainLatam — EEG, ERP, EEG-TMS and EEG-fMRI Research Technology in Latin America.

https://brainlatam.com/

Official Product Documentation

Brain Products — New Releases
https://www.brainproducts.com/new-releases/

BrainAmp II and BrainAmp II MR — Official Flyer
https://www.brainproducts.com/download/flyer-brainamp/

BrainVision Recorder 2 and Composer — Product Announcements
https://www.brainproducts.com/new-releases/

Technical publication note: Published specifications describe the first BrainAmp II release in November 2026. Product codes and package contents reflect the provided launch information. Exact technical specifications, validated configurations, software versions and regional availability should be confirmed with the manufacturer before procurement.


BrainAmp II | Brain Products | SfN 2026 | BrainLatam

#BrainAmpII #BrainAmpIIMR #BrainProducts #SfN2026 #EEGAmplifier #EEGSystem #EEGResearch #ERP #TMSEEG #EEGfMRI #BrainVisionRecorder2 #BrainVisionComposer #Neurotechnology #BrainLatam

#eegmicrostates #neurogliainteractions #eegmicrostates #eegnirsapplications #physiologyandbehavior #neurophilosophy #translationalneuroscience #bienestarwellnessbemestar #neuropolitics #sentienceconsciousness #metacognitionmindsetpremeditation #culturalneuroscience #agingmaturityinnocence #affectivecomputing #languageprocessing #humanking #fruición #wellbeing #neurophilosophy #neurorights #neuropolitics #neuroeconomics #neuromarketing #translationalneuroscience #religare #physiologyandbehavior #skill-implicit-learning #semiotics #encodingofwords #metacognitionmindsetpremeditation #affectivecomputing #meaning #semioticsofaction #mineraçãodedados #soberanianational #mercenáriosdamonetização
Besa EasyCAP Brain Products NIRx Artinis
Author image

Jackson Cionek

New perspectives in translational control: from neurodegenerative diseases to glioblastoma | Brain States